Welcome to Our Company -

Infrared Temperature Sensors PyroUSB

Infrared Temperature Sensors PyroUSB

Product Details:

X

Product Description

Features:

New compact housing only 61 mm long including cable glands
Temperature ranges from -40C to 2000C
Fully configurable via USB using Modbus protocol. Cable and software included
Peak and valley hold mode for measuring objects on conveyors
Stainless steel housing, sealed to IP65
Quick and easy installation
Use Calex or third-party software

 General Specifications:

Attribute

PUA2 Models

PUA5 Models

PUA8 Models

Temperature Range

LT: 45C* to 300C

GLT: 50C to 1000C

-40C to 1000C


PT: 100C to 400C

GHT: 200C to 1650C



MT: 250C to 1000C




HT: 450C to 2000C



Field-of-View

15:1 (with LT or PT temperature range)




25:1 (with MT or HT temperature range)




75:1 (with MT or HT temperature range)




25:1


30:1 or Close Focus 5 mm @ 100 mm

Output

Two-wire 4 to 20 mA (linear with temperature)



Configuration

Via PC port conforming to USB 2.0



Accuracy

1% of reading or 2C, whichever is greater (PUA2 models)




1C or 1% of reading, whichever is greater (PUA5 and PUA8 models)



Repeatability

0.5% of reading or 0.5C, whichever is greater



Emissivity Setting

Adjustable 0.1 to 1.0 via software



Response Time, t90

200 ms



Spectral Range

PUA2: 2.0 to 2.6 m

PUA5: 5 m

PUA8: 8 to 14 m

Supply Voltage

24 V DC (28 V DC max)



Sensor Voltage

6 V DC min



Max Loop Impedance

900 @ 24 V DC



Maximum Span (analog output)

Full temperature range



Minimum Span (analog output)

100C



Software Specifications (CalexConfig):

Attribute

Value

Operating System

Windows

Features

Temperature display, scrolling temperature chart, sensor configuration, data acquisition with scheduled start, on-screen alarm

Data Log File Format

.csd (comma-separated text format, may be imported to spreadsheet software such as Excel)

Data Transmission Protocol

Modbus over USB (it is possible to communicate with the sensor for temperature measurement and configuration using third-party software. Protocol information is provided in the instruction manual.)

Environmental Specifications:

Attribute

Value

Environmental Rating

IP65

Ambient Temperature Range

0C to 70C (cooling option available for use in higher ambient temperatures)

Relative Humidity

95% max. non-condensing

Please note: The given measured spot size contains 90% of the energy detected by the sensor. We normally recommend the target is at least twice as large as the given measured spot for maximum accuracy. Sensors may be used at longer distances than the above diagrams show. There is no maximum measurement distance in clean air; this is because PyroUSB sensors detect only the wavelengths of infrared radiation that are not absorbed by the atmosphere.

Mechanical Specifications

Attribute

Value

Construction

Stainless Steel

Dimensions

27.6 x length 61 mm including cable glands

Thread Mounting

M20 x 1 mm pitch, length 15 mm

Weight with Output Cable

155 g

Output Cable Length

1 m (longer cable available to order)

USB Cable Length

1.8 m