General Specifications:
Attribute | Value |
---|---|
Temperature Range | -20C to 1000C |
Interface | Raw CAN |
Accuracy | 1% of reading or 1C, whichever is greater |
Repeatability | 0.5% of reading or 0.5C, whichever is greater |
Emissivity Setting | Adjustable via CAN, 0.2 to 1.0 |
Response Time, t90 | 200 ms (90% response) |
Spectral Range | 8 to 14 m |
Supply Voltage | 12 to 24 V DC |
Supply Current | 50 mA max. |
CAN Protocol Specifications:
Attribute | Value |
---|---|
Baud Rate | 250 kbps |
Data Format | 8 bytes total: |
Bytes 1-4: Object temperature as floating point | |
Bytes 5-8: Ambient temperature as floating point | |
Transmit Interval | 200 ms |
CAN ID Range | ID can be set between 0 and 255 as a 4-byte unsigned integer |
Emissivity | Adjustable from 0.2 to 1.0 as a 4-byte floating point |
Mechanical Specifications:
Attribute | Value |
---|---|
Construction | Stainless Steel |
Dimensions | 18 mm diameter x 103 mm long |
Thread Mounting | M16 x 1 mm pitch |
Cable Length | 1m (longer lengths available to order) |
Weight with Cable | 95 g |
Environmental Specifications:
Attribute | Value |
---|---|
Environmental Rating | IP65 |
Ambient Temperature Range | 0C to 90C |
Relative Humidity | 95% max. non-condensing |
Please note: The given measured spot size contains 90% of the energy detected by the sensor. We normally recommend the target is at least twice as large as the given measured spot for maximum accuracy. Sensors may be used at longer distances than the above diagrams show. There is no maximum measurement distance in clean air; this is because the PyroCAN detects only the wavelengths of infrared radiation that are not absorbed by the atmosphere.